BQRCR - PR-1141 PC-57 BRICK RED, PART A

Product Identification

Product ID:PR-1141 PC-57 BRICK RED, PART A
MSDS Date:02/26/1991
FSC:8030
NIIN:00N036545
MSDS Number: BQRCR

Responsible Party
PRODUCTS RESEARCH & CHEMICAL CORP
5430 SAN FERNANDO RD
GLENDALE, CA 91209
US

Emergency Phone: 800-228-5635;800-424-9300(CHEMTREC)

Info Phone: 818-240-2060

Preparer: A. O.

Cage: DO563

Contractor
PRODUCTS RESEARCH & CHEMICAL
1800 GLENDALE, CA 91209 US

Telephone: 818-240-2060

Cage: DO563

Ingredients

3.94.

CAS: 110-43-0

RTECS: MJ5075000

Fraction By Weight: 34%

OSHA PEL 100 PPM

ACGIH TLV: 50 PPM


IRON (III) OXIDE; (RED IRON OXIDE)

CAS: 1309-37-1

RTECS: NO7400000

OSHA PEL 10 MG/M3 (FE)

ACGIH TLV: 5 MG/M3(FE),B2; 9293


HYDROPHOBIC SILICA

CAS: 68611-44-9


SATURATED POLYESTER POLYOL

CAS: 38499-32-1


ACRYLIC SUBSTITUTED DIOXAZOLIDONE


SILICIC ACID (H*2SIO*3), CALCIUM SALT; (CALCIUM

CAS: 10101-39-0

RTECS: VV9170000

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EYES: MAY CAUSE BURNING, TEARING AND
REDDENING. SKIN: PROLONGED EXPOSURE MAY CAUSE DRYING AND CRACKING
OF SKIN. POSSIBLE DERMATITIS. INHALATION: MAY CAUSE DIZZINESS,
DROWSINESS AND FATIGUE. INGESTION: MAY CAUSE DROWSINESS, DIZZINESS
AND NAUSEA.
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:EYES: FLUSH WITH LUKE WARM WATER FOR AT LEAST 15 MINUTES. IF
SYMPTOMS PERSIST, CONSULT PHYSICIAN. SKIN: WASH WITH SOAP AND
WATER. IF SYMPTOMS PERSIST, CONSULT PHYSICIAN. INHALATION: REMOVE
TO FRESH AI R. IF SYMPTOMS ARE PRESENT CONSULT A PHYSICIAN.
INGESTION: CALL MD IMMEDIATELY .

Fire Fighting

Flash Point Method:PMCC
Flash Point:108F,42C
Lower Limits:1.1%
Upper Limits:7.9%
Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL, FOAM, WATER FOG.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT . USE WATER TO COOL HEAT EXPOSED CONTAINERS.
Unusual Fire/Explosion Hazard:HIGH TEMPERATURES MAY CAUSE PRESSURE
BUILDUP IN CLOSED CONTAINERS.

Accidental Release

Spill Release Procedures:REMOVE ALL IGNITION SOURCES. WEAR NIOSH/MSHA
APPROVED AIR-SUPPLIED RESPIRATOR FOR MAJOR UNVENTILATED SPILL.
COVER WITH ABSORBENT. SCOOP INTO CONTAINERS. CLEAN-UP RESIDUE WITH
1,1,1-TRICHLOROETHANE.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:NONE.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.

Exposure Controls

Respiratory Protection:WHEN SPRAYING, APPLYING IN CONFINED AREAS, OR IN
OTHER CIRCUMSTANCES LIKELY TO PRODUCE AIRBORNE LEVELS OF SOLVENT IN
EXCESS OF PEL, USE A NIOSH/MSHA APPROVED ORGANIC VAPOR CARTRIDGE
RESPIRATOR OR AIR- SUPPLIED RESPIRATOR.
Ventilation:GENERAL VENTILATION TO MAINTAIN VAPORS BELOW PEL.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:CHEM WORK GOG/FULL LGTH FACESHLD .
Other Protective Equipment:DURING SPRAY APPLICATION, COMPLETE SKIN
PROTECTION IS REQUIRED.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.

Chemical Properties

HCC:F4
Vapor Density:SEE ING 1
Spec Gravity:1.19
Evaporation Rate & Reference:SEE ING 1
Solubility in Water:NEGLIGIBLE
Appearance and Odor:THIN, DULL RED LIQUID.
Percent Volatiles by Volume:51

Stability

Stability Indicator/Materials to Avoid:YES
NONE KNOWN.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:OXIDES OF CARBON.

Disposal

Waste Disposal Methods:EPA WASTE NO. D-001. DISPOSE OF SPILLAGE IN
COMPLIANCE WITH FEDERAL, STATE AND LOCAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.